Electrical Characteristics
MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W)
Power at MPP2 |
PMPP |
280 |
285 |
290 |
Short Circuit Current* |
ISC |
9.41 |
9.46 |
9.52 |
Open Circuit Voltage* |
VOC |
38.97 |
39.22 |
39.48 |
Current at MPP* |
IMPP |
8.84 |
8.91 |
8.98 |
Voltage at MPP* |
VMPP |
31.67 |
31.99 |
32.29 |
Efficiency2 |
η |
≥ 16.8 |
≥ 17.1 |
≥ 17.4 |
MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NOC3
Power at MPP2 |
PMPP |
207.0 |
210.7 |
214.4 |
Short Circuit Current* |
ISC |
7.58 |
7.63 |
7.68 |
Open Circuit Voltage* |
VOC |
36.37 |
36.61 |
36.84 |
Current at MPP* |
IMPP |
6.93 |
6.99 |
7.05 |
Voltage at MPP* |
VMPP |
29.87 |
30.15 |
30.42 |
11000 W/m², 25 °C, spectrum AM 1.5 G 2 Measurement tolerances STC ± 3 %; NOC ± 5 % 3 800 W/m², NOCT, spectrum AM 1.5 G * typical values, actual values may differ