| FLEXIBLE APPLICATION
Convenient for new installation and retrofit Compatible with both lithium-ion and leadacid batteries Energy trading ready with 3rd-party EMS to maximise ROI |
SAFE AND RELIABLE
Built-in surge arresters and residual current protection Durable finish with high anti-corrosion enclosure |
| SMART MANAGEMENT
High self-consumption with optimised built-in EMS Free online monitoring to enhance energy management for end user, installer and retailer Remote firmware update and customisable settings |
EASY INSTALLATION
Cleaner and simpler install with EPS built-in to inverter Custom-fit mounting plate with built-in level Fast and easy commissioning via front panel LCD or App |
- Description
- Additional information
- Circuit Diagram
- System Data
- Mechanical Data
- Battery Data
- Protection
- AC In & Out Data
- DC Input Data
- Backup Data
- Inquiry form
| Product | Sungrow SH5K-30 Hybrid Single Phase Inverter |
|---|
Circuit Diagram

System Data
| Max. efficiency | > 97.7 % |
| Max. European efficiency | > 97.1 % |
| Max. charge / discharge efficiency | > 94.0 % |
| Isolation method (solar) | Transformerless |
| Isolation method (battery) | HF |
| Ingress protection rating | IP65 |
| Operating ambient temperature range | -25 ℃~60 ℃ (>45 ℃ derating) |
| Relative humidity range | 0%~100% |
| Cooling method | Natural convection |
| Max. operating altitude | 2000m |
| Display | Graphic LCD |
| Communication | 2 × RS485, Wi-Fi , CAN, Ethernet |
| Power Management | 1 × Digital Output |
| Earth alarm | Email, buzzer inside |
| PV connection type | MC4 |
| AC connection type | Clamping yoke connector |
| Certification | AS4777,IEC 62109-1, IEC62109-2,IEC62477-1, IEC 62040-1, EN 61000-6-1/-3,
ABNT NBR 16149: 2013 ABNT NBR 16150: 2013 |
Mechanical Data
| Dimensions (W * H * D) | 457 mm * 515 mm * 170 mm |
| Mounting method | Wall-mounting bracket |
| Weight | 22 kg |
Battery Data
| Battery type | Li-ion battery / Lead-acid battery |
| Battery voltage | 48 V (32 V–70 V) |
| Max. charge / discharge current | 65 A / 65 A |
Protection
| Anti-islanding protection | Yes |
| AC short circuit protection | Yes |
| Leakage current protection | Yes |
| DC switch (solar) | Optional |
| DC fuse (battery) | Yes |
| Overvoltage Category | III [MAIN], II [PV] [BATTERY] |
AC In & Out Data
| Nominal AC output power | 5000 W |
| Nominal AC ouput current | 22.7 A |
| Max. AC output apparent power | 5000 VA |
| Max. AC output current | 22.7 A |
| Max. AC input power | 8000 W |
| Max. AC input current | 36.4 A |
| Nominal AC voltage | 220 Vac / 230 Vac / 240 Vac |
| AC voltage range | 176 Vac~276 Vac |
| Nominal grid frequency | 50 Hz / 60 Hz |
| Grid frequency range | 45~55 Hz / 55~65 Hz (this may vary with grid standards) |
| THD (Total Harmonic Distortion) | <3 % (of nominal power) |
| DC current injection | <0.5 % (of nominal current) |
| Power factor | >0.99 at default value at nominal power (adj. 0.8
overexcited / leading to 0.8 underexcited / lagging) |
DC Input Data
| Max. PV input power | 6500 W |
| Max. PV input voltage | 600 V |
| Startup voltage | 125 V |
| Nominal input voltage | 350 V |
| MPP voltage range | 125 V – 560 V |
| MPP voltage range for nominal power | 240 V – 520 V |
| No. of MPPTs | 2 |
| Max. number of PV strings per MPPT | 1 / 1 |
| Max. PV input current | 22 A (11 A / 11 A) |
| Max. current for input connector | 12 A |
| Short-circuit current of PV input | 24 A (12 A / 12 A) |
Backup Data
| Nominal voltage | 220 Vac / 230 Vac / 240 Vac (±2 %) |
| Total hamonic factor output voltage | 2 % (full resistive load) |
| Frequency range | 50 Hz / 60 Hz (±0.2 %) |
| Switch time to emergency mode | <20 ms |
| Power factor | 0.8 overexcited / leading to 0.8 underexcited / lagging |
| Backup nominal AC output power | 3000 W / 3000 VA |
| Max. output power | 5000W / 5000 VA |
| Max. output power (battery) | 3000 W / 3000 VA |
| Peak output power,Duration | 6000 VA, 10S |