Menu Close

Q.Power-G4.1 300-310

Q.Power-G4.1 300-310

The new high-performance module Q.PEAK-G4.1 is the ideal solution for
all applications thanks to its innovative cell technology Q.ANTUM. The
world-record cell design was developed to achieve the best performance
under real conditions – even with low radiation intensity and on clear,
hot summer days.

Category:

 

Q-Cells Performance Warranty

At least 98 % of nominal power duringfirst year. Thereafter max. 0.54 % degradation per year. At least 93.1 %
of nominal power up to 10 years. At least 85 % of nominal power up to 25 years.
All data within measurement tolerances.
Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country.

Mechanical Specification

Format 65.7 in × 39.4 in × 1.26 in (including frame)
(1670 mm × 1000 mm × 32 mm)
Weight 40.78 lbs (18.5 kg)
Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass with anti-reflection technology
Back Cover Composite film
Frame Black anodised aluminum
Cell 6 × 10 polycrystalline solar cells
Junction box 2.60-3.03 in × 3.54-4.53 in × 0.59-0.75 in (66-77 mm × 90-115 mm ×
15-20 mm), Protection class ≥ IP67, with bypass diodes
Cable 4 mm² Solar cable; (+) ≥ 39.37 in (1000 mm), (−) ≥ 39.37 in (1000 mm)
Connector Multi-Contact, MC4, IP67 and IP68

Properties for system design

Maximum System Voltage VSYS [V] 1000 (IEC) / 1000 (UL) Safety Class II
Maximum Series Fuse Rating [A DC] 20 Fire Rating C (IEC) / TYPE 1 (UL)
Design load, push (UL)2 [lbs/ft2] 75 (3600 Pa) Permitted module temperature

on continuous duty

− 40 °F up to +185 °F

(− 40 °C up to +85 °C)

Design load, pull (UL)2 [lbs/ft2] 55.6 (2666 Pa) see installation manual

Temperature Coefficients

Temperature Coefficient of ISC α [% / K] + 0.04 Temperature Coefficient of VOC β [% / K] − 0.28
Temperature Coefficient of PMPP γ [% / K] − 0.39 Normal Operating Cell Temperature NOCT [°F] 113 ± 5.4 (45 ± 3 °C)

Electrical Characteristics

MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W)

Power at MPP2 PMPP [W] 300 305 310
Short Circuit Current* ISC [A] 9.77 9.84 9.91
Open Circuit Voltage* VOC [V] 39.76 40.05 40.33
Current at MPP* IMPP [A] 9.26 9.35 9.44
Voltage at MPP* VMPP [V] 32.41 32.62 32.83
Efficiency2 η [%] ≥ 18.0 ≥ 18.3 ≥ 18.6

MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NOC3

Power at MPP2 PMPP [W] 222.0 225.7 229.4
Short Circuit Current* ISC [A] ] 7.88 7.94 7.99
Open Circuit Voltage* VOC [V] 37.19 37.46 37.73
Current at MPP* IMPP [A] 7.27 7.35 7.43
Voltage at MPP* VMPP [V] 30.52 30.70 30.87

1000 W/m2, 25 °C, spectrum AM 1.5 G 2 Measurement tolerances STC } 3 %; NOC } 5 % 3 800 W/m2, NOCT, spectrum AM 1.5 G * typical values, actual values may differ

Q.antum

MORE LIGHT. MORE PERFORMANCE. MORE ELECTRICITY. – Q.ANTUM
Q.ANTUM Technology supercharges ordinary solar cells and modules. Q.ANTUM delivers exceptional performance under real-world conditions. We designed Q.ANTUM to generate more power when the sun is rising, setting, or even behind clouds. You’ll also see higher yields in the middle of hot and sunny summers, and during clear fall and winter days, when the sun is not as high in the sky. We enhanced low-light performance, but also the output of our modules across a range of temperatures – all to bring you higher profits.

Packaging Information

Number of Modules per Pallet 32
Number of Pallets per 53′ Container 30
Number of Pallets per 40′ Container 26
Pallet Dimensions ( L × W × H ) 68.7 in × 45.3 in × 46.1 in

(1745 mm × 1150 mm × 1170 mm)

Pallet Weight 1396 lbs (633 kg)